84
internal display of incoming data would display very slowly and the tool would appear to crash. As of
MS-DMT v1.00 Build 1.0.0.0 the Data Port can now be active without the need of an external terminal
being active, however “enable buffer overrun” must be enable if a VCP port is being used and the
external terminal flow control must not being using any handshaking or asserting the RTS line for PTT.
The MS-DMT tool should always be started with the Data Port enabled before any external
terminal application is started.
The Data Port supports COM port selections between 1..16 to activate and 0 to disable. For
additional details see Appendix E.